Might be something more to add to the window classes. Mike, Whenever possible they try to avoid window welds. Window Welds (Tube Patches, Window Patch, Flush Inserts). Note how tight the space is. That is likely a 2 1/2" dia. Doesn't a 7018 welded to ss have a tendency to crack, unlike ss to mild steel.
Follow Us on Facebook and LinkedIn for future updates and notifications. and also teach window welds. Isokinetic Sampling Nozzles (Probes) for measuring Liquids and Gases, including Water, Steam, and Natural Gas. I normally messaged him on Facebook as he was getting home from work lol, Stick Welding/Arc Welding - Shielded Metal Arc Welding, Tig Welding - Tig Welding Aluminum - Tig Welding Techniques - Aluminum Tig Welding, Mig and Flux Core - gas metal arc welding & flux cored arc welding, Stick Welding/Arc Welding - Shielded Metal Arc Welding, Welding Certification - Stick/Arc Welding, Tig Welding, Mig Welding Certification tests - Welding Tests of all kinds, Welding Projects - Welding project Ideas - Welding project plans, Welding Jobs - Industrial Welding Jobs - Pipe Welding Jobs - Tig Welding Jobs, Classifieds - Buy, Sell, Trade Used Welding Equipment, instructions how to enable JavaScript in your web browser, https://www.youtube.com/watch?v=lM-fdhnjlTg, http://www.weldingdata.com/WindowWelds.htm. GAustin: I have a ? These are SA 210 Core with a .100" thick layer of 300 series SS over the OD, These are sometimes used in Black Liquor Recovery boilers in paper mills. The window welds shown on my site are for tangent tube composite boiler tubes. Thanks Stu Bass. Either open root lo-hi, 5p, tig or backing strap. They enable to proceed to the simultaneous weld end preparations on the tubes of the boiler panel and to the excavation of the membrane walls. TES Group Inc. has repair procedures, welding procedures and experienced personnel to execute Window Weld repairs on boiler tubes where accessibility around the complete circumference of the tube is restricted. This page was generated at 05:21 AM.
Usually it's whatever the composition of the tube is what you weld it with.
9021 24th Street, Edmonton, AlbertaT6P 1L2, Tel: 587-760-3200 | Toll-Free: 877-857-3377. National Board of Boiler & Pressure Vessel Inspectors to register NB pressure equipment with the following ASME designator: (U, A, PP, S). ACSA (Alberta Construction Safety Association) - Membership. The only window welds we ever put in were on some radiant reheat tubes that had zero clearance to water wall tubes on one side. These are some of the easier tubes to weld in a boiler. Beveling - Pipe Facing - Orbital cutting - Counterboring - Surfacing - Boring, Tube, Valve, Flange, Elbow & Sheet Metal Manufacturers, BB Series - High speed pipe beveling machine. Personally I NEVER relit a used rod. Combustion boiler design. http://www.osti.gov/bridge/product.bosti_id=631170, If this is your first visit, be sure to
According to my sauces(BBQ and tomato) it is common here in AUS, both for repairs and (apparently) close outs where the final lot of tubes are welded in, cutting off access. In tangent tube furnaces with welded membrane, window welds are necessary. Two boilermakers buddy welding a reheat tube.
also. I'm not versed in power station or boiler stuff, so it's all just observation. Add your name to our mailing list and receive this valuable information by email. Plus few new power stations have been built here in recent years. The ones where you can get someone on both sides are usually better than the ones that have to be airbagged and welded one side at a time. Awesome. Than furnace design is not common. Warning: blocking cookies prevents the proper operation of the site.
, , , Movable joint for water wall tube of boiler, Method for repairing straight arm metal thin walled tube by applying laser and micro-arc spark composite technology, Pre-Machined Window Weld for Breached Tubing, Repairing process of nozzle of secondary fuel nozzle component of combustion engine, Corner diversion steel pipe fracture restoration method, Method for replacing worn tubes in a gas hood, Tube repair welding method and equipment therefor, Method and apparatus and prefabricated replacement tube for localized waterwall repair, Steam generator heating tube repair means and repair method, Flexible stabilizer for degraded heat exchanger tubing, Air heater with flue gas, installation method, air pipe component for air heater with flue gas, Method of repairing a defective portion in a fluid carrying tube, Steam generator tube failures: World experience in water-cooled nuclear power reactors during 1972, Reliability and durability from large heat recovery steam generators, Method of repairing exhaust heat recovery boiler, Maintaining and repairing heat exchanger tubes, Economizer, boiler, and repair method of heat exchanger tube, Operation assistance method and operation assistance system, Thermal and Mechanical Design Guidelines and General Considerations for the Proper Design, and Location, of Various Types of Service Connections on Steam Surface Condensers, Replacement pressure parts consideration for replace in-kind, upgrade or redesign, Method and arrangement in cooling medium circulation of a recovery boiler, The Effect of Materials and Design Geometry on Tube Plugs at High Pressure Steam Super Heater, Main factors causing damage to the high-temperature heating surfaces used in power-generating boilers, Failure-cause analysis: feedwater heaters. Always grab a new one cause the company is buying them and it lessens the chance of porosity on the pick up. Someone should know. ASME Certificate of Authorization from the American Society of Mechanical Engineers (ASME) for the following ASME designators S, A, U, & PP, National Board of Boiler & Pressure Vessel Inspectors - Certificate of Authorization - TES Group Inc. is authorized to use to R Symbol in accordance with the provisions of the National Board Inspection Code and NB-415, Accreditation of R Repair Organ. Reheats can have 3-4 metal combinations according to the place in the row and elevation. Is that similar to where they cut a window in the pipe and weld it from inside? These types of repairs are recognized by NBIC, ASME PCC-2 and API as acceptable repair methods. TES Group Inc. is pleased to announce that it has become a member of Avetta. Good fun though. I think its done it AUS a bit, but we can be a bit backwards here. 29340 Industrial Way #402 Evergreen And have never done this weld procedure with ss then finish with lo-hi. This website uses some cookies. Looks like a ton of fun.
: 3.3.x, Stick Welding Tips, Certification tests, machines, projects. Also I notice a SS root then a 7018 fill and cover. Thanks for the information. Most boiler inspectors (Hartford especially) really frown on window welds. check out the.
E-Mail: contact@protemusa.com. The PROTEM GR-Series are OD clamping machines, specifically designed for boiler panels and waterwall cutout windows. They were used commonly in Black Liquor Recover boilers in paper mills.
(in Victoria anyway). Hated working on those damn radiant tubes. This type of repair is executed from one side of the boiler water walls typical of tangent tube construction. x .220 wall. This is the cap so they have a TIG root in, filled and capped w/ 8018 or 9018.
I'am never to old to learn. I'll post it on my other page, to get a feel for how common it actually is here. I know. Final report, Design and Modification of Heat Recovery Steam Generators for Cycling Operations, Design Guidelines for the Safe Operation of Steam Surface Condenser Turbine Bypass on Combined Cycle Power Plants, The Considerations for Reviewing the Effects of Power Uprates, Including Repowering, on Existing Steam Surface Condensers, Ep: the epo has been informed by wipo that ep was designated in this application, Wipo information: entry into national phase. Don't take this wrong please but I have done windows for almost 30 yrs. ver. All times are GMT-6. CO 80439 | USA On your site for this you said a composit tube, do you mean a stainless to a 90 series tube like transition tubes in the superheat area? I never encountered the need fir a window weld in a power boiler however my experience is only mine. Copyright TES Group Inc. All rights reserved. If you continue navigation, you accept the use of cookies.